CHAPTER 3 SYSTEM DATA PROGRAMMING
– 155 –
NWA-008855-001 Rev.1.0
avch3001.fm
MAINTENANCE DATA PROGRAMMING
DESCRIPTION DATA
Define fault information to be stored. (1)
(2)
450
1: To store
Specify the processing at the time of the fault
information memory overflow.
(1)
(2)
451
0 : No fault information is registered
1 : Fault information is overwritten
Assign the registration of fault information
into memory and the control of the external
alarm.
(1)
(2)
Y=2
12 : CS fault occurred
2B: CS fault occurred
3B: CS fault recovered
0: Registration of fault memory/No output
of External alarm
1: Registration of fault memory/External
alarm is MN alarm
2: Registration of fault memory/External
alarm is MJ alarm
3: Registration of fault memory/External
alarm kind is determined in standard data
NONE : No Registration of fault memo-
ry/No output of external alarm
START
CM08
CMEA
END