CHAPTER 3 SYSTEM DATA PROGRAMMING
– 125 –
NWA-008855-001 Rev.1.0
avch3001.fm
DESCRIPTION DATA
Specify the Sender prepause timing to the
trunk route.
NOTE: To reduce the connecting time, it is
preferable to shorten the prepause
timing (i.e., second data=03 (1.5
seconds)).
•
(1)
(2)
Y=21
00-63: Trunk Route No.
00: 0 second 08 : 6.0 seconds
01: 0.5 seconds 09 : 7.0 seconds
02: 1.0 second 10 : 8.0 seconds
03: 1.5 seconds 11 : 9.0 seconds
04: 2.0 seconds 12 : 10.0 seconds
05: 2.5 seconds 13 : 11.0 seconds
06: 4.0 seconds 14 : 12.0 seconds
07: 5.0 seconds 15 : 3.0 seconds
Specify the DP Inter-Digital Pause to the trunk
route.
•
(1)
(2)
Y=23
00-63: Trunk Route No.
0: 300 ms. 4 : 700 ms.
1: 400 ms. 5 : 900 ms.
2: 500 ms. 6 : 1100 ms.
3: 600 ms. 7 : 800 ms.
Specify the DTMF Inter-Digital Pause to the
trunk route.
NOTE: To reduce the connecting time, it is
recommended to shorten the DTMF
inter-digital Pause timing (Y=24),
i.e., second data=2 (80 ms.). Y=26,
i.e., second data=0 (64 ms.).
•
(1)
(2)
Y=24
00-63: Trunk Route No.
0: 32 ms. 4 : 160 ms.
1: 64 ms. 5 : 192 ms.
2: 80 ms. 6 : 240 ms.
3: 96 ms. 7 : 128 ms.
B
CM35
C
TRUNK DATA PROGRAMMING (For Adjunct Analog)