CHAPTER 3 SYSTEM DATA PROGRAMMING
– 122 –
NWA-008855-001 Rev.1.0
avch3001.fm
DESCRIPTION DATA
Associate the Virtual station number and the
PS station number.
(1)
(2)
Y=10
X-XXXXXXXX: Virtual Station No. as-
signed by CM14
X-XXXXXXXX: PS Station No. assigned
by CM1C
Specify the timing until sending the reverse
signal to the calling PS station for connecting
the line.
(1)
(2)
Y=0
110
01-99: 4-396 seconds
(4 second increments)
If no data is set, the reverse signal is not sent to
the calling PS station.
A
CM5A
CM41
END