CHAPTER 2 INSTALLATION
– 65 –
NWA-008855-001 Rev.1.0
avch2001.fm
Example of MDF Cross Connection for CS (BS31)
NOTE 1: RJ-45 Modular plug is highly recommended.
Keep all wiring straight to the plug and perform all reverses at the cross connect for future
changes.
NOTE 2: For the 2 wire Connection, terminal No. 4 and No. 5 are not used.
TERMINAL
NUMBER
COLOR
TERMINAL
NUMBER
FUNCTION
TERMINAL EQUIPMENT CSI
1 blue a Not used Not used
2 orange b Not used Not used
3 black c
Signal/Feed Signal/Feed
4redd
Feed (/Not used) NOTE 2 Feed (/Not used) NOTE 2
5 green e
Feed (/Not used) NOTE 2 Feed (/Not used) NOTE 2
6 yellow f
Signal/Feed Signal/Feed
7 brown g Not used Not used
8 slate h Not used Not used
1
2
3
4
5
6
7
8
(8)
(1)
Term in a l
number
Front view Side view
CONNECTION OF LEGACY CS