Program
No.
Program Name Input Data Default
22-01-07 System Options for Incoming Calls - DID Incom-
ing Ring Group No Answer Time
0 ~ 64800 seconds 20
22-11-08 DID T
ranslation Table - Maximum Number of DID
Calls
0 ~ 128 (0 = No limit)
0 = No Limit (Can receive as
many calls as you have available
trunks.)
0
22-11-09 DID Translation Table - Music on Hold Source 0 = IC/MOH Port
1 = BGM Port
0
DDI Mode Switching
Program
No.
Program Name Input Data Default
22-02-01 * Incoming Call Trunk Setup - Trunk Service Type 0 = Normal
1 = VRS (second dial tone if no
VRS installed)
2 = DISA
3 = DID
4 = DIL
5 = Tie Line
6 = Delayed VRS
7 = ANI/DNIS
8 = DID (DDI) Mode Switching
0
14-05-01 Trunk Group -
Trunk Group Number 1 ~ 128 = Trunk Port
0 ~ 50 = Group Number
1 ~ 128 = Priority
1
22-09-01 DID Basic Data Setup - Dial-In Receive digit 1 ~ 8 2
22-17-01 * Dial-In Conversion Table Area Setup for Time
Pattern - Received Dial
Up to eight digits No Setting
22-17-04 * Dial-In Conversion Table Area Setup for Time
Pattern - Dial-In Conversion Table Number
1 ~ 1000 (These are the table
entries in PRG 22-11.)
0
22-11-01 DID Translation Table - Received Number Maximum eight digits
(0 ~ 9,
, #, @)
Refer to the Program-
ming Manual.
22-11-02 * DID Translation Table - Target Number Maximum 36 digits
(0 ~ 9,
, #, @)
Refer to the Program-
ming Manual.
20-07-26 * Class of Service Options (Administrator Level) -
Dial-In Mode Switch
0 = Off (Station cannot control
DDI switching.)
1 = On (Station can control DDI
switching.)
COS1 ~ 14/COS15 = 1
15-07-01 Programmable Function Keys 88 = Dial In Mode Switching Refer to the program-
ming manual for the
default values and for
all other available op-
tions in this command.
Direct Call by Time Schedule:
Program
No.
Program Name Input Data Default
11-10-35 Service Code Setup (for System Administrator) -
Dial-In Mode Switching
0~9,
, # Maximum of 8 digit 609
ISSUE 1.0 SL2100
Features and Specifications Manual 1-255