GS716Tv2 and GS724Tv3 Software Administration Manual
2-6 Configuring System Information
v1.0, July 2009
method is selected, SNTP information is accepted only from SNTP servers defined on the device
using the SNTP Server Configuration page.
The device retrieves synchronization information, either by actively requesting information or at
every poll interval.
Time Configuration
Use the Time Configuration page to view and adjust SNTP parameters.
To display the Time Configuration page:
1. Click System Management Time SNTP Global Configuration in the navigation
menu.
2. Use the Time option to set the time locally on the switch. Select the Clock Source as Local by
checking the radio button to configure the local time.
3. In the Date field, enter the date in the DD/MM/YYYY format.
4. In the Time field, enter the time in HH:MM:SS format.
5. When the Clock Source is set to Local, the Time Zone field is grayed out (disabled):
6. Click Apply to send the updated configuration to the switch. Configuration changes take
effect immediately.
Note: If you do not enter a Date and Time, the switch will calculate the date and time
using the CPU’s clock cycle.