GS716Tv2 and GS724Tv3 Software Administration Manual
2-24 Configuring System Information
v1.0, July 2009
2. If you make any changes to the page, click Apply to apply the new settings to the system.
LLDP Port Settings
Use the LLDP Port Settings page to specify LLDP parameters that are applied to a specific
interface.
To display the LLDP Port Settings page:
1. Click SystemLLDP Advanced LLDPPort Settings in the navigation tree.
Figure 2-13
Table 2-15. LLDP Configuration Fields
Field Description
LLDP Properties
TLV Advertised Interval Specifies the interval at which frames are transmitted. The default is 30
seconds, and the valid range is 1–32768 seconds.
Hold Multiplier Specifies multiplier on the transmit interval to assign to Time-to-Live
(TTL). The default is 4, and the range is 2–10.
Reinitializing Delay Specifies the delay before a reinitialization. The default is 2 seconds,
and the range is 1–10 seconds.
Transmit Delay Specifies the interval for the transmission of notifications. The default is
5 seconds, and the range is 5–3600 seconds.