09. When the [Set] key is released, all LEDs are switched off.
10. Send an opening command by pressing the [Open] key to perform a
complete opening manoeuvre.
Open
Stop
Set
Close
L1 L2 L3 L4 L5 L6 L7 L8
BusT4
Fuse 3.15AF
Stop
OSE
8K2
PP
Open
Close
Flash
2
Bluebus
to push
buttons
to internal
control
to internal
brake
-20° C +55° C
DIC1
N19771
11. Send a closing command by pressing the [Close] key to perform a
complete closing manoeuvre.
Open
Stop
Set
Close
L1 L2 L3 L4 L5 L6 L7 L8
BusT4
Fuse 3.15AF
Stop
OSE
8K2
PP
Open
Close
Flash
2
Bluebus
to push
buttons
to internal
control
to internal
brake
-20° C +55° C
DIC1
N19771
CAUTION! – The learning phases must never be interrupted. If this oc-
curs, the entire learning procedure must be repeated. At the end of the
learning phase, if LEDs “L3” and “L4” ash, this means that there is an
error. The position recognition procedure can be repeated at any time
also after the installation.
3.15 - Recognition of limit positions on opening and closing with
the use of MEIN family inverter
5 positions can be programmed, as described below:
Position LED Meaning
A1 L1 Maximum opening position. When the door reaches
this position it stops
RA1 L2 Position when the deceleration starts during the open-
ing manoeuvre. When the door reaches this position,
the motor decelerates and reaches the minimum
speed.
AP L5 Partial opening position. It is the position in which the
door stops after giving a partial opening command.
RA0 L7 Position when the deceleration starts during the clos-
ing manoeuvre. When the door reaches this position,
the motor decelerates and reaches the minimum
speed.
A0 L8 Maximum closing position. When the door reaches this
position it stops.
If the door is in the closing position, it must be positioned manually at about
50 cm from the ground by using the emergency manoeuvre system (see motor
instruction manual) to prevent, in case of inverted rotation, the load-bearing
ropes (sectional doors) from leaving their seat or the excessive tightening of the
shutter (rolling shutters).
Caution! - If the direction of rotation does not correspond to the direc-
tion set (Open = opening direction), you must leave the "Recognition
of opening and closing positions” procedure and activate the function
“Inverted rotation direction”; refer to Table 5.
To carry out the procedure, proceed as described below:
01. Press and hold down [Set] and
[Close] keys for 3 seconds to
start the position memorisation
phase.
LED L1 ashes: programming po-
sition A1
Open
Stop
Set
Close
L1 L2 L3 L4 L5 L6 L7 L8
BusT4
Fuse 3.15AF
Stop
OSE
8K2
PP
Open
Close
Flash
2
Bluebus
to push
buttons
to internal
control
to internal
brake
-20° C +55° C
DIC1
N19771
02. Use the [Open] or [Close] key to move the door to the maximum
opening position.
03. Press the [Set] key for 3 seconds
to conrm position A1.
LED L1 stays on.
LED L2 ashes: programming po-
sition RA1
Open
Stop
Set
Close
L1 L2 L3 L4 L5 L6 L7 L8
BusT4
Fuse 3.15AF
Stop
OSE
8K2
PP
Open
Close
Flash
2
Bluebus
to push
buttons
to internal
control
to internal
brake
-20° C +55° C
DIC1
N19771