1 - PRODUCT DESCRIPTION AND INTENDED USE .......................................................1
2 - INSTALLATION ...........................................................................................................1
2.2 - Product application limits ...............................................................................................................1
2.3 - Typical system ................................................................................................................................ 1
2.4 - Installation of the control unit .......................................................................................................... 2
3 - ELECTRICAL CONNECTIONS ...................................................................................4
3.1 - Connection of the three-phase mains power cable for control units DIC4001, NDCC4002,
NDCC4005 ...........................................................................................................................................4
3.2 - Connection of the mono-phase mains power cable for control unit NDCC2301 .............................4
3.3 - Description of the electrical connections to the logic board NDA001 ..............................................4
3.4 - Description of the electrical connections to the power board .......................................................... 6
3.5 - Electrical connections of the control unit .........................................................................................6
3.6 - Connection of other devices to the control unit ...............................................................................7
3.7 - Photocells ......................................................................................................................................7
3.8 - MOTB digital selector and proximity reader for MOMB transponder cards ...................................... 7
3.9 - STOP Input ................................................................................................................................... 8
3.10 - Connecting a radio receiver .......................................................................................................... 8
3.11 - Initial start-up and electrical connections ...................................................................................... 8
3.12 - Recognition of the connected devices .......................................................................................... 9
3.13 - Recognition of limit positions on opening and closing ................................................................... 9
3.14 - Recognition of limit positions on opening and closing with electronic limit switch (encoder) ..........9
3.15 - Recognition of limit positions on opening and closing with the use of MEIN family inverter ..........10
3.16 - Recognition of limit positions on opening and closing with mechanical limit switch ..................... 10
3.17 - Oview programming unit ...........................................................................................................11
3.18 - Use with MEIN series inverter ..................................................................................................... 11
4 - TESTING AND COMMISSIONING ............................................................................12
4.1 - Testing .........................................................................................................................................12
4.2 - Commissioning ............................................................................................................................12
5 - CONTROL UNIT PROGRAMMING ...........................................................................12
5.1 - Level one programming (ON-OFF functions) ................................................................................. 12
5.2 - Level two programming (adjustable parameters) ...........................................................................13
5.3 - ADDITIONAL INFORMATION ........................................................................................................ 15
5.4 - DIAGNOSTICS ............................................................................................................................. 17
6 - WHAT TO DO IF... (troubleshooting guide) ................................................................18
7 - GENERAL WARNINGS.............................................................................................20
8 - PRODUCT DISPOSAL..............................................................................................21
9 - TECHNICAL CHARACTERISTICS OF THE PRODUCT .............................................22
10 - OPERATION MANUAL ............................................................................................. II
CE DECLARATION OF CONFORMITY .............................................................................III
IMPORTANT!
Before carrying out any type of operation or
procedure, carefully read the general warnings in
this manual (chapter 7),
application limits (paragraph 2.2)
1
PRODUCT DESCRIPTION AND INTENDED USE
DIC4001 - NDCC4002 - NDCC4005 are control units to be used to automate
Rolling shutters and sectional doors with three-phase motors.
NDCC2301 is a control unit to be used to automate sectional doors with mono-
phase motors or for sectional and high-speed doors automated by a three-
phase motor with MEIN inverter on board.
Model Door type Connection Max. power
DIC4001
Rolling door opener
Sectional
Three-phase 1.1KW
NDCC4002
Rolling door opener
Sectional
Three-phase 2.2KW
NDCC4005
Rolling door opener
Sectional
Three-phase 5.5KW
NDCC2301
Sectional
High-speed door
Mono-phase
MEIN family inverter
1.5KW
1.1KW / 2.2KW
CAUTION! – All uses other than the intended use described and use
in environmental conditions other than those described in this manual
should be considered improper and forbidden!
All the control unit models may be connected to all the common safety elements.
To open and close a door, just press the specic button installed on the cover or
the external button or via the radio receiver.
CAUTION! – The control units described in this instruction manual may
not be used in the zones at risk of explosion.
2
INSTALLATION
2.1 - Preliminary checks for installation
Before proceeding with installation, check the condition of the product
components, suitability of the selected model and conditions of the intended
installation environment.
Ensure that all material used is in perfect condition and suitable for use.
Check that all use conditions are within the product application limits
(paragraph 2.2) and within the value limits reported in the “Product technical
specications”.
Check that the intended installation area is suitable for the overall size of the
product (g. 1).
Ensure that the selected surfaces for product installation are solid and
guarantee a stable xture.
Make sure that the xing zone is not subject to ooding. If necessary, mount
the product suitably raised from the ground.
Check that the space around the product provides easy and safe access.
Make sure that all the electrical cables to be used are of the type listed in Table
1.
Check that in the automation there are the mechanical stops when closing and
opening
2.2 - Product application limits
The product may only be used as reported in the table below:
Control
unit
Control unit power
supply
Type of motor*
DIC4001
NDCC4002
NDCC4005
Three-phase 3x230 Vac,
3x400 Vac - 50/60Hz
Three-phase 3x230 Vac, 3x400 Vac
with Nice encoder or mechanical limit
switches
NDCC2301
Mono-phase 230 Vac -
50/60Hz
Mono-phase 230 Vac with Nice en-
coder or mechanical limit switches
Motor with mono-phase MEIN family
inverter
(*) In compliance with the corresponding application limits.