TABLE 1 - Technical specications of electrical cables (g. 2)
Connection Cable type Maximum length allowed
A: CONTROL UNIT POWER SUPPLY cable 4 x 1 mm
2
5 m (note 1)
B: MOTOR cable for the Nice gearmotors, dedicated cables sold as
accessories.
ask the manufacturer of the gearmotor for different
brands
3 – 5 – 9 – 11 m
C: FLASHING LIGHT cable
with aerial
2 x 1 mm
2
(for ashing light)
RG58 shielded cable type (for aerial)
10 m
D: BLUEBUS DEVICE cable 2 x 0.5 mm
2
15 m (note 2)
E: KEY-OPERATED SELECTOR SWITCH cable 2 cables 2 x 0.25 mm
2
10 m (note 3)
F: Spiral cable for sensitive edge Nice Spiral cable available as accessory 50 m
Note 1 – If the power supply cable exceeds 5 m in length, it is necessary to use a cable with a larger cross-section.
Note 2 – If the Bluebus cable is longer than 10 m and reaches up to a maximum of 15 m, a cable with a larger cross-sectional area is required (2x1mm
2
).
The Bluebus cable must be separated from the other cables.
Note 3 – These 2 cables may be replaced by a single cable 4 x 0.5 mm
2
.
CAUTION! – The cables used must be suited to the installation environment.
3
A B
4
A B C