VBA28001-R.3813.A
- A71 ・ D3100 -
Measurement of consumption current value
Refer to "Measurement of consumption current value" of ADJUSTMENT Separate Volume
①
for
details.
Standard:
Main SW/OFF (NOT any button pressed) 200μA or less
Main SW/ON (Half-release timer: OFF) 190μA or less
Main SW/ON (Half-release timer: ON) 250mA or less
Main SW/ON (TFT monitor: Light up) 280mA or less
During LV (Live View) 550mA or less
During recording movies 700mA or less
•
Tool (Device)
Use Nikon product.
Power supply
(10V 5A)
Digital meter Converted
power connector
EP-5A