EasyManua.ls Logo

Nikon D3100 VBA28001 - Measurement.of.consumption.current.value

Nikon D3100 VBA28001
156 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VBA28001-R.3813.A
- A71 D3100 -
Measurement of consumption current value
Refer to "Measurement of consumption current value" of ADJUSTMENT Separate Volume
for
details.
Standard:
Main SW/OFF (NOT any button pressed) 200μA or less
Main SW/ON (Half-release timer: OFF) 190μA or less
Main SW/ON (Half-release timer: ON) 250mA or less
Main SW/ON (TFT monitor: Light up) 280mA or less
During LV (Live View) 550mA or less
During recording movies 700mA or less
Tool (Device)
Use Nikon product.
Power supply
(10V 5A)
Digital meter Converted
power connector
EP-5A
User ID:INC