VBA28001-R.3813.A
- R4 ・ D3100 -
Items Judgment standard Remarks
Clock accuracy Difference par month: ± 90 seconds (20
℃)
Wave clock
BC level Check the level by
digital multi-meter
Battery life CIPA standard
Room temperature:
550 frames or more
0
℃
: 500 frames or more
Professional mode
Room temperature:
2000 frames or more
0
℃ :
1600 frames or more
・
Setting: Factory default (Exposure mode: M, VR: OFF,
others: default settings, shooting luminance face: LV12)
・
Lens: AF-S VR 18-55/3.5-5.6G
・
Temperature: 23
℃
±2
℃ ・ ・
Humidity: 50
%
±20
%
・
Operation: Repeat the following at 30 sec. in one cycle.
AF lens scanning cycled once Repeat shooting of Repeat shooting of Repeat shooting of
odd/even numbered shots When the number of shots When the number of shots When the number of shots
remaining becomes 0, format card After 8 sec. of half- After 8 sec. of half- After 8 sec. of half-
releasing timer passes, power OFF
Caution)
Assuming that the power SW becomes off
every 10-frame release, perform ISC (Image Sensor
Cleaning) operation.
(
When the timer becomes OFF after "10×n " frame
shooting, and when the timer becomes ON before "11×n"
frame shooting, perform ISC operation each. n
≧
1
)
・
Setting: ISO 100, exposure mode: M, 1/250, F16,
AF-C, operation mode: Continuous (shooting) mode:
Continuous, VR: OFF, luminance face: LV12, image
quality: BASIC, image size: M, white balance: A
・
Lens: AF-S VR 18-55/3.5-5.6G
・
Temperature: 20
℃
, 0
℃
・
Operation: Repeat the following cycle:
Press halfway Format card Repeat the below Format card Repeat the below Format card Repeat the below Repeat the below Repeat the below
□-framed instruction When the number of shots When the number of shots When the number of shots
remaining becomes 0, insert/remove card Format card Format card Format card
Caution) Assuming that the power SW becomes off
every 10-frame release, perform ISC operation.
1st level
To 2 level (Remaining charge decreased) 7410mV ± 100mV
Back to 1 (Remaining charge increased) 7610mV ± 100mV
2nd level
To 3 level (Remaining charge decreased) 7310mV ± 100mV
Back to 2 (Remaining charge increased) 7710mV ± 100mV
3rd level
To 4 level (Remaining charge decreased) 7120mV ± 100mV
Back to 3 (Remaining charge increased) 8120mV ± 100mV
4th level
To nal level (Remaining charge decreased) 5150mV ± 100mV
Back to 4 (Remaining charge increased) 7000mV ± 100mV
Operation Shots captured even number
of times
Shots captured odd number ot
times
Release shutter WITHOUT ring built-in
ash.
WITH ring built-in ash.
(
M-ash/FULL setting
)
Indications
playedback on
LCD monitor
4 seconds 4 seconds
Press halfway for 3 sec. AF scanning cycled 3 times AF scanning cycled 3 times AF scanning cycled 3 times
Release shutter 6 times continuously Playback on Release shutter 6 times continuously Playback onPlayback onPlayback on
TFT for 4 sec. Wait until half-release timer becomes Wait until half-release timer becomes Wait until half-release timer becomes
OFF: 8 sec.