9-6. Procedure for upgrading RISC rmware:
 ・ After preparing the CF card, copy the latest version ( XXXX. BIN) into the root directory.
 ・ Insert the CF card, and select "FIRMWARE VERSION" from the SETUP menu.
 ・ Follow the instructions on screen for version upgrading. It takes approx. 3-4 minutes.
 ・ Check the version of rmware by "RISC VERSION" of the image adjustment software.
 Note:
In case incorrect les are included in the CF card, the details for updating are not displayed even
after selecting "FIRMWARE VERSION" from the SETUP menu.
9-7. TFT adjustment
 ・Provide the power for the camera via AC adapter.
 ・Connect the camera and PC via USB cable.
 ・Turn the camera ON.
  Flicker adjustment
 ・Usually the default value can be used, and this adjustment is not necessary.
 ・If icker can be checked with eyes, drag the slider and adjust the camera’s monitor not to icker.
 ・Remove the USB cable from the camera, and also remove the AC adapter without turning the power OFF.
 
  Hue adjustment
 ・Usually the default value can be used, and this adjustment is not necessary.
 ・If improper hue can be checked with eyes, drag the slider and adjust the camera’s monitor not to icker.
 ・Remove the USB cable from the camera, and also remove the AC adapter without turning the power OFF.
  Luminance adjustment
 ・Usually the default value can be used, and this adjustment is not necessary.
 ・If improper hue can be checked with eyes, drag the slider and adjust the camera’s monitor not to icker.
 ・Remove the USB cable from the camera, and also remove the AC adapter without turning the power OFF.