EasyManua.ls Logo

Nikon D80 VBA14001 - Measurement of Consumption Current Value

Nikon D80 VBA14001
111 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-  -
Q0340
060411
VBA14001-R.3694.A
Measurement of Consumption current value
When this camera is used for measuring the consumption current value, connect the battery tool (J61213), and
turn the change-SW to OFF. Then make measurements based on the following.
7.8V 0.3Ω
Test item Standard Test condition
Main SW
OFF
All operational buttons are NOT pushed.
200 μ A or less
ref. above.
AF50/1.4D
EV12
Main SW
ON (Half-release timer OFF) 200 μ A or less
Main SW
ON (Half-release timer ON) 200 μ A or less
Main SW
ON (Illumination ON) 300 μ A or less
Main SW
ON (TFT ON)
   
1 A or less
Inspection standards
Turn change-SW to OFF.
Caution:
When the consumption current value is measured, backup battery must be fully charged.

Table of Contents