7. Required equipment and conditions
※ AC adapter EH-5 and USB cable (mini B type) UC-E4 are used for all adjustments so they are not
specied in the list.
Item Required device Setting/Remarks
1
Gr/Gb difference compensation
adjustment (G lter)
・5100K color viewer J63070
(ex-model viewer J63049 is also available.)
・Luminance meter BM-3000 J63068
・Tool lens (to x aperture) J61185
・SP2 (G lter) J63086
Luminance LV13 equivalent
Aperture F5.6
2
Sensitivity adjustment
・5100K color viewer J63070
(ex-model viewer J63049 is also available.)
・Luminance meter BM-3000 J63068
・Tool lens (to x aperture) J61185
・ND lter
(ND8×1+ND4×1)
Luminance LV13 equivalent
Aperture F8
52 mm,
Use the packaged product; 5-step light
reduction
3
Shading adjustment
・5100K color viewer J63070
(ex-model viewer J63049 is also available.)
・Luminance meter BM-3000 J63068
・Tool lens (to x aperture) J61185
・ND lter (ND8×1)
Luminance LV13 equivalent
Aperture F5.6
Use the packaged product; 3-step light
reduction
4
Gr/Gb compensation adjustment
(R/B lter)
/ Line crawl adjustment
・5100K color viewer J63070
(ex-model viewer J63049 is also available.)
・Luminance meter BM-3000 J63068
・Tool lens (Fixed aperture) J61185
・SP3 (R lter) J63087
・SP1 (B lter) J63085
Luminance LV13 equivalent
Aperture F5.6
5
Sensitivity ratio adjustment
・ Shutter tester
・Luminance meter BM-3000 J63068
・Tool lens (to x aperture) J61185
・5100K color viewer J63070
(ex-model viewer J63049 is also available.)
Luminance LV9
Aperture F5.6; No lter
Inspection luminance LV13 equivalent
6
Image shutter inspection and
adjustment
・ Shutter tester
・Luminance meter BM-3000 J63068
・Tool lens (to x aperture) J61185
Luminance LV9, 15
Aperture F5.6
7
Pixel defect compensation -
black point
・5100K color viewer J63070
(ex-model viewer J63049 is also available.)
・Luminance meter BM-3000 J63068
・Tool lens (to x aperture) J61185
Luminance LV13 equivalent
Aperture F5.6
8
Pixel defect compensation -
white point
Body cap or lens cap Environmental temperature approx. 20
- 25℃
9
Getting of reference values Same as "Sensitivity adjustment" and "sen-
sitivity ratio adjustment".
No lter when sensitivity ratio
reference value is calculated.
10
Factory default setting None
11
Checking of adjustment value None
12
Reading of RISC version None
13 TFT adjustment None