Programming Functions 84Service Manual – Advenger, 2800ST, 3800ST, BR 755, BR 855
Changing Program Settings - Advenger / BR 755, 855 (Disc and Cyl.)
1 To enter this Hidden Menu, turn the key switch Off, then press and hold the Scrub and Vacuum switches together.
2 Turn key switch back On and hold the switches for 2 seconds until the Solution and Scrub indicators both turn on.
3 Release both switches - the display will now read “Programming Options.” Scroll through the menus using the Solution + or - switches and
enter the program number corresponding to the needed function.
4 To enter a submenu, press the Solution switch.
5 To save and go back to the main menu, press the Scrub switch.
6 To exit the hidden menu, turn the key switch off.
Prog. Function Option 1 Option 2 Option 3 Option 4, etc.
1 DECK TYPE 28” disc /
BR 755
28” Cyl /
BR 755 C
34” disc /
BR 855
--
2 CHEMICAL SELECTION AXP On
US mode: X:XXX
EDS On
EU mode: %
AXP/EDS Off
3 DETERGENT MODE Off
no Evergreen
(board default)
Mode 1
US Evergreen On
Mode 2
EU or non-Evergreen
preset
4 VACUUM SELECTION 1 (single) 2 (dual) --
5 LOW VOLTAGE CUTOUT Wet battery 80% Gel/AGM Battery 70% --
6 MAXIMUM SCRUB SPEED 100% 90% 80% 50%
7 LOCK OUT BRUSH PRES
(displayed pressure is locked out)
Low Med High Low & Medium, Low &
High, High & Medium
8 LOCK OUT SOLUTION
(displayed rate is locked out)
Low Med High Low & Medium, Low &
High, High & Medium
9 RECOVERY TANK FULL
(automatic shutoff turned on)
ENABLED DISABLED -- --
10 CHEMICAL RATE BIAS NONE (equal) +10% MORE CHEM -10% LESS CHEM --
11 DECK DOWN TIME Incremental from 1 to 5 seconds in 0.1 second intervals
12 RESTORE FACTORY DEFAULTS NO YES -- --
14 FAULT RECALL No faults
occurred - display
is “-”
Error codes To erase history, press the Solution switch while
in this mode.
15 FAULT DETECTION ENABLED DISABLED
17 BACKUP ALARM VOL Off Low Med High
18 FWR ALARM VOL Off Low Med High
19 HORN VOL Off Low Med High