Programming Functions 88Service Manual – Advenger, 2800ST, 3800ST, BR 755, BR 855
Program Options (REV)
Program options must be set whenever the Main Controller has been replaced.
• ScrubDeckType - This function congures the control unit current settings and ow rate settings for
each of the scrub deck types. Note: After replacing the controller the machine will not operate until a deck
type has been selected.
• ChemicalSelection - Used to let the controller know whether the onboard detergent dispensing system
has been installed and which market area the machine is in. The market area determines whether to
show the detergent dilution rate as a ratio (US-style) or percentage (EU/Global-style) .
• Vacuummotorquantityselection - The main controller must be programmed for the number of
vacuum motors installed so that the current overload protection and recovery tank full will function
properly.
• LowVoltageCutoutSelection- The purpose of the special low battery voltage cutout function is to
help prolong battery life. The scrub deck will be raised and the brush motors and solution solenoid valve
will turn OFF automatically and cease to function when the batteries discharge to the selected cutout
level. The cutout level is adjustable between two settings. The standard setting (wet cell/lead acid) is
20.55 volts and alternate setting (gel/maintenance free) is 21.75 volts.
• MaximumScrubSpeed - The control system is programmed to limit the maximum speed while
scrubbing to a value less than that allowed for driving when not scrubbing (100%, 90%, 80%, 70%, and
60%).
• LockOutBrushPressure - Used to lock out any brush pressure settings Low, Medium, High, Low and
Medium, Low and High, High and Medium. During normal operation, the pressure setting(s) that are
locked out will not be able to be selected. Default is “None”
• LockOutSolutionFlowRate - Used to lock out any solution ow rate settings: Low (Normal), Medium
(Heavy), High (Extreme), Low and Medium, Low and High, High and Medium. During normal operation,
the ow rate(s) that are locked out will not be able to be selected.
• RecoveryTankFullEnable/Disable - Used to enable or disable Recovery Tank Full automatic shutoff
feature. Enable means that the automatic shutoff feature is turned on; disable means that the automatic
shutoff feature is turned off.
• ChemicalRatioBias - Used to increase or decrease the chemical mix rate by 10% to achieve a more or
less concentrated mix than that determined by user programmed ratio
• DeckDownTimePeriodAdjustment - When the scrub on/off switch is pressed, the control unit
will automatically lower the deck for a specied amount of time. The time that the deck is lowered is
adjustable from 1 second to 5 seconds in 0.1 second increments.
• RestoreFactoryDefault - This submenu should reset all parameters stored in the EEPROM except
Brush on Time. Note: after restoring factory defaults, all of the program options must be reviewed and set
appropriately. The machine will not work until at least the deck type is selected.
• DisplayRevisionLevel - The LCD display will show the revision level of the software in the control
board.
• FaultRecall - Whenever the control unit detects an electrical system fault, one or more error codes are
displayed and stored in the EEPROM. If it is desired, the error code (if any) from the previous operation
for the machine can be recalled for troubleshooting purposes. If no fault code is present, the display will
show a “-“
• FaultDetection - Normally, the main control unit will perform checks of the electrical system during
operation. If a fault occurs in a particular system, that system (and possibly others) will be shut down.
This can make troubleshooting the system difcult. This option will allow service personnel to disable
some of the fault detection checks to facilitate troubleshooting. This will not disable the over-current
protection on any of the systems.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance Advenger 3400ST and is the answer not in the manual?

Nilfisk-Advance Advenger 3400ST Specifications

General IconGeneral
BrandNilfisk-Advance
ModelAdvenger 3400ST
CategoryFloor Machine
LanguageEnglish

Related product manuals