RECOVERY SYSTEM 58Service Manual – Advenger, 2800ST, 3800ST, BR 755, BR 855
Replacing a Vacuum Motor
WARNING!
DISCONNECT BATTERIES BEFORE SERVICING.
RECOVERY TANK REMOVAL
1 See Figure 26. Drain the Recovery Tank (A) using the Drain Hose(B).
2 Disconnect the Recovery Hose (C) from the squeegee.
3 Disconnect the vacuum motor wiring from the main harness. NOTE: Also disconnect optional Beacon wiring if installed.
4 Remove the Recovery Tank (A) from the machine.
FIGURE 26