EasyManua.ls Logo

NIVELCO MultiCONT - Page 50

NIVELCO MultiCONT
105 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
prw2101a0600p_01
50 / 105
NIV128: NIVELCO device specific commands optimized for VOL measurement
EchoTREK 4-wire. EchoTREK 2-wire.
EasyTREK EasyTREK
NIVOTRACK NIVOCAP
P01 PV Base 3. Pos. 4. Pos PV Base 3. Pos. 4. Pos PV Base 3. Pos. 4. Pos PV Base 3. Pos. 4. Pos.
0 DIST LEV SR* Curr. DIST LEV SR Curr. DIST LEV SR Curr. % LEV 0 Curr.
1 LEV LEV SR Curr. LEV LEV SR Curr. LEV LEV SR Curr. LEV LEV 0 Curr.
2 LE% LEV SR Curr. LE% LEV SR Curr. LE% LEV SR Curr. LE% LEV 0 Curr.
3 VOL LEV SR Curr. VOL LEV SR Curr. VOL LEV SR Curr. VOL LEV 0 Curr.
4 VO% LEV SR Curr. VO% LEV SR Curr. VO% LEV SR Curr. VO% LEV 0 Curr.
5 FLO LEV SR Curr. FLO LEV SR Curr. - - - - - - - -
* SR (sensor range): Value of the difference in level between the „Maximum range” ( H=P04 ) and the „Minimum range” (dead zone - near blocking) in %
(empty tank: DIST=H 0%, full tank: DIST=”Minimum range” 100% ). Necessary for displaying the bargraph.
NIV129: NIVELCO device specific commands optimized for FLOW measurement
(TOT1 and TOT2 in float format)
EchoTREK 4-wire EchoTREK 2-wire
EasyTREK EasyTREK
NIVOTRACK NIVOCAP
P01 PV Base 3. Pos. 4. Pos PV Base 3. Pos. 4. Pos PV Base 3. Pos. 4. Pos PV Base 3. Pos. 4. Pos
0 DIST LEV TOT1 TOT2 DIST LEV TOT1 TOT2 DIST LEV 0 0 % LEV 0 0
1 LEV LEV TOT1 TOT2 LEV LEV TOT1 TOT2 LEV LEV 0 0 LEV LEV 0 0
2 LE% LEV TOT1 TOT2 LE% LEV TOT1 TOT2 LE% LEV 0 0 LE% LEV 0 0
3 VOL LEV TOT1 TOT2 VOL LEV TOT1 TOT2 VOL LEV 0 0 VOL LEV 0 0
4 VO% LEV TOT1 TOT2 VO% LEV TOT1 TOT2 VO% LEV 0 0 VO% LEV 0 0
5 FLO LEV TOT1 TOT2 FLO LEV TOT1 TOT2 - - - - - - - -

Table of Contents