prw2101a0600p_01
50 / 105
NIV128: NIVELCO device specific commands optimized for VOL measurement
EchoTREK 4-wire. EchoTREK 2-wire.
EasyTREK EasyTREK
NIVOTRACK NIVOCAP
P01 PV Base 3. Pos. 4. Pos PV Base 3. Pos. 4. Pos PV Base 3. Pos. 4. Pos PV Base 3. Pos. 4. Pos.
0 DIST LEV SR* Curr. DIST LEV SR Curr. DIST LEV SR Curr. % LEV 0 Curr.
1 LEV LEV SR Curr. LEV LEV SR Curr. LEV LEV SR Curr. LEV LEV 0 Curr.
2 LE% LEV SR Curr. LE% LEV SR Curr. LE% LEV SR Curr. LE% LEV 0 Curr.
3 VOL LEV SR Curr. VOL LEV SR Curr. VOL LEV SR Curr. VOL LEV 0 Curr.
4 VO% LEV SR Curr. VO% LEV SR Curr. VO% LEV SR Curr. VO% LEV 0 Curr.
5 FLO LEV SR Curr. FLO LEV SR Curr. - - - - - - - -
* SR (sensor range): Value of the difference in level between the „Maximum range” ( H=P04 ) and the „Minimum range” (dead zone - near blocking) in %
(empty tank: DIST=H 0%, full tank: DIST=”Minimum range” 100% ). Necessary for displaying the bargraph.
NIV129: NIVELCO device specific commands optimized for FLOW measurement
(TOT1 and TOT2 in float format)
EchoTREK 4-wire EchoTREK 2-wire
EasyTREK EasyTREK
NIVOTRACK NIVOCAP
P01 PV Base 3. Pos. 4. Pos PV Base 3. Pos. 4. Pos PV Base 3. Pos. 4. Pos PV Base 3. Pos. 4. Pos
0 DIST LEV TOT1 TOT2 DIST LEV TOT1 TOT2 DIST LEV 0 0 % LEV 0 0
1 LEV LEV TOT1 TOT2 LEV LEV TOT1 TOT2 LEV LEV 0 0 LEV LEV 0 0
2 LE% LEV TOT1 TOT2 LE% LEV TOT1 TOT2 LE% LEV 0 0 LE% LEV 0 0
3 VOL LEV TOT1 TOT2 VOL LEV TOT1 TOT2 VOL LEV 0 0 VOL LEV 0 0
4 VO% LEV TOT1 TOT2 VO% LEV TOT1 TOT2 VO% LEV 0 0 VO% LEV 0 0
5 FLO LEV TOT1 TOT2 FLO LEV TOT1 TOT2 - - - - - - - -