9 Tabular overview of the program procedures I-Charge
© Nortec Electronics 2018 105
9.6.1 Program 510: I-Charge Pb battery sealed MIL
9.6.2 Program 511: I-Charge Pb battery sealed commercial
9.6.3 Program 516: I-Charge Pb battery vented commercial
10: Pb battery sealed MIL
 select Batteryprocessing:

P5: I-Charge
Enter:
Nominal voltage
Rated capacity
Charging current
Charging time span
Switch off voltage of each cell
Step 1:
I-Charge with entered charging current for the input time span. If shut down voltage is reached the
program will be terminated.
End of program
9.6.4 Programm 520: I-charge NiCd battery (manufacturer independent)
20: NiCd battery (manufacturer independent)
 select Batteryprocessing:

P5: I-Charge
Enter:
Number of cells
Rated capacity
Charging current
Charging time span
Switch off voltage of each cell
Step 1:
I-Charge with the entered charging current for the input time span.
If the shut down voltage is reached the program will be terminated.
End of program