9 Tabular overview of the program procedures Charge
66 © Nortec Electronics 2018
9.3.1 Program 210: Charge Pb battery sealed MIL
10: Pb battery sealed MIL
select Batteryprocessing:
P2: Charge
Enter:
Nominal voltage
Rated capacity
Step 1:
In case the battery voltage before starting charging is below 2.15
V × numbers of cells:
Precharging with 2.4
V × number of cells until charging current of 0.4
C
1
is reached.
This step will not be printed if it takes less than 3 minutes.
Step 2:
I-charge with 0.4
C
1
until a charging voltage of 2.4
V × number of cells is reached.
Step 3:
U-charge with 2.4
V × number of cells until the charging current is decreased to 0.02
C
1
.
End of program
Time monitoring:
Precharge maxiumum 2 hours, I- and U-charge maximum 8 hours, capacity maximum 1.5 × C