5 Technical data Electrical input and output parameter
20 © Nortec Electronics 2018
5 Technical data
5.1 Electrical input and output parameter
Input voltage : 230
VAC 10% (single phase)
Feed frequency : 45 to 60
Hz
Input power : 3000
VA
Mains fuse external : 16
A semi time-lag
Fan power : About 100/300
litre/minute
Charging current range : 0.5 – 60
A (to 31
V)
Charging voltage range : 0.5 – 40
A (> 31
V)
Discharging current range : 0.5 – 60
A
Charging voltage range : 0.1 – 40
V (using NiCd reload upto 41.5
V)
Discharging voltage range : 0.1 – 40
V
Voltage precision : < 0.1
% adjusted value plus 5
digits
Current precision : < 3
% adjusted value 5
d
igits
Temperature precision : < 2C
Isolation : VDE 0160, class I
Safety class : IP20
Working temperature : 0 - + 45C
Weight : About 32 kg (in19’’-housing without battery cable)
Dimensions : Width 504
mm, height
242 mm, depth
400 mm
Distance from obstacles for used air : > 100
mm
Interfaces : USB 2.0; RS232, Ethernet RJ45
5.2 Temperature range
The functions of the device are guaranteed in temperature range from 0 C upto +45 C.
The precision of the visual display and the printed record of the charging and discharging parame-
ter correspond to the precision specified in chapter 5.1.
The precision of output data is guaranteed in the temperature range from 0 C to +45 C for 2
years starting from the delivery date of the device.
5.3 Calibration
We recommend a first calibration by the manufacturer Nortec Electronics or by an authorized part-
ner company after 2 years.
After that for safety related engineering a yearly calibration and maintenance is recommend. Addi-
tionally, please pay attention to the internal and external rules laid down by the competent authori-
ties.