9 Tabular overview of the program procedures
116 © Nortec Electronics 2018
9.9.6 Program 820: Constant Voltage Supply NiCd battery (manufacturer independ-
ent)
9.9.7 Program 821: Constant Voltage Supply NiCd battery HAWKER
20: NiCd battery (manufacturer independent)
select Batteryprocessing:
P8: Constant Voltage Supply
Enter:
Charging current
Nominal voltage
Step 1:
Constant voltage supply with 1.42 V for each cell and with the entered current.
Time span: 7 hours
End of program
9.9.8 Program 822: Constant Voltage Supply NiCd battery SAFT
22: NiCd battery SAFT
select Batteryprocessing:
P8: Constant Voltage Supply
Enter:
Charging current
Nominal voltage
Step 1:
Constant voltage supply with 1.42 V for each cell and with the entered current.
Time span: 5 hours.
End of program