8 Program selection The display screen for program 420
46 © Nortec Electronics 2018
8.5.2 Program 420 Step 2
NiCd battery (manufacturer independent)
Program: Maintenance
P420:S2: I-CHARGE 1
24.64V
04.00A
00.5Ah
007MIN
15.01.15 19:50:00
--
.
-
°C
1 Program number
Kind of treatment 4 = Maintenance
Battery type 20 = NiCd battery (manufacturer independent)
2 Step number = S2
3 Step type = I-CHARGE 1
4 19:50:00 = present time
5 24.64
V = present battery voltage
6 04.00
A = present charging current
The charging current in the test routine for
NiCd batteries is selected in a way that the
capacity will be charged within 1
h. 4
A if it is
the correct current for a 4
Ah battery.
5
6
4
3
2
1