8 Program selection The display screen for program 420
© Nortec Electronics 2018 49
8.5.5 Program 420 Step 5
NiCd battery (manufacturer independent)
Program: Maintenance
P420:S5: I-CHARGE 2
30.98V
04.00A
04.00Ah
060MIN
16.01.15 00:34:38
--
.
-
°C
1 Program number
Kind of treatment 4 = Maintenance
Battery type 20 = NiCd battery (manufacturer independent)
2 Step number = S5
3 Step type = I-CHARGE 2
4 00:34:38 = present time
5 30.98
V = present battery voltage
6 4.0
A = present charging current
The charging current with the test program for
NiCd batteries is chosen in a way that the
capacity is charged again within 1
h.
4
A if a 4
Ah battery is in use.
7 4.00
Ah Capacity loaded in 60 minutes in Ah.
8 0060
MIN Display of charging time with positive sign
(forward count).
5
6
7
8
4
3
2
1

Table of Contents