9 Tabular overview of the program procedures Maintenance
© Nortec Electronics 2018 97
9.5.8 Programm 422: Maintenance NiCd battery SAFT
Name according to manual: Capacity Check or Regular Check
22: NiCd battery SAFT
select Batteryprocessing:
P4: Maintenance
Refer also to program P322: Capacity Test.
The program Capacity Test involves only the discharge with capacity test!
Enter:
Number of cells
Rated capacity
Query, when the cell test measurement should be taken (80 - 100% or 48 - 60 minutes)
Query, if Capacity Check or Regular Check
When “Regular Check” has been selected:
Waiting after program step “Deep Discharge”? (see step 2)
Regular check requires an automated cell tester.
General Overhaul starts after the reassembly of the battery.