EasyManua.ls Logo

Nortec UL60 - Page 81

Nortec UL60
119 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9 Tabular overview of the program procedures Capacity test
© Nortec Electronics 2018 81
Example:
================================
COPYRIGHT NORTEC
2014-15 UL60 V 1.0 16.06.15
SN: 160001
--------------------------------
DATE: 28.06.15
BATTERY NO:
USER NO:
NOM.VOLTAGE: 24.00 V
CAPACITY: 040.0 Ah
PROGRAM: 321
NiCd Battery HAWKER
Capacity Test
--------------------------------
PROGRAM START 08:14:12
VOLTAGE = 26.96 V
--------------------------------
P321:S1: 09:02:44
DISCHARGE
VOLTAGE = 23.93 V
CURRENT = 40.01 A
CAPACITY = 031.8 Ah
= 079 %
TIME = 048 MIN
--------------------------------
CELL 01: 1.196 V
CELL 02: 1.194 V
CELL 20: 1.187 V
--------------------------------
P321:S1: 09:14:39
DISCHARGE
VOLTAGE = 20.00 V
CURRENT = 40.01 A
CAPACITY = 039.8 Ah
= 099 %
TIME = 060 MIN
--------------------------------
BATTERY EVALUATION
C>80%: Battery is OK
CAPACITY = 039.8 AH
= 099 %
PROGRAM AUTOMATICALLY FINISHED
================================

Table of Contents