MS51
Nov. 28, 2019 Page 402 of 491 Rev 1.00
MS51 32K SERIES TECHNICAL REFERENCE MANUAL
ScnIE – SC Interrupt Enable Control Register
Auto Convention Error Interrupt Enable Bit
This field is used to enable auto-convention error interrupt.
0 = Auto-convention error interrupt Disabled.
1 = Auto-convention error interrupt Enabled.
Block Guard Time Interrupt Enable Bit
This field is used to enable block guard time interrupt.
0 = Block guard time interrupt Disabled.
1 = Block guard time interrupt Enabled.
Transfer Error Interrupt Enable Bit
This field is used to enable transfer error interrupt. The transfer error states is at SC0TSR register
which includes receiver break error BEF(SC0TSR[6]), frame error FEF(SC0TSR[5]), parity error
PEF(SC0TSR[4]), receiver buffer overflow error RXOV(SC0TSR[0]) and transmit buffer overflow
error TXOV(SC0TSR[2]).
0 = Transfer error interrupt Disabled.
1 = Transfer error interrupt Enabled.
Transmit Buffer Empty Interrupt Enable Bit
This field is used to enable transmit buffer empty interrupt.
0 = Transmit buffer empty interrupt Disabled.
1 = Transmit buffer empty interrupt Enabled.
Receive Data Reach Interrupt Enable Bit
This field is used to enable received data interrupt.
0 = Receive data interrupt Disabled.
1 = Receive data interrupt Enabled.