EasyManua.ls Logo

Nuvoton NuMicro MS51PC0AE - Page 402

Default Icon
491 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MS51
Nov. 28, 2019 Page 402 of 491 Rev 1.00
MS51 32K SERIES TECHNICAL REFERENCE MANUAL
ScnIE SC Interrupt Enable Control Register
Register
SFR Address
Reset Value
SC0IE
DCH, Page 2
0000_0000 b
SC1IE
E4H, Page 2
0000_0000 b
SC2IE
ECH, Page 2
0000_0000 b
7
6
5
4
3
2
1
0
-
-
-
ACERRIEN
BGTIEN
TERRIEN
TBEIEN
RDAIEN
-
-
-
R/W
R/W
R/W
R/W
R/W
Bit
Name
Description
7:4
-
Reserved
4
ACERRIEN
Auto Convention Error Interrupt Enable Bit
This field is used to enable auto-convention error interrupt.
0 = Auto-convention error interrupt Disabled.
1 = Auto-convention error interrupt Enabled.
3
BGTIEN
Block Guard Time Interrupt Enable Bit
This field is used to enable block guard time interrupt.
0 = Block guard time interrupt Disabled.
1 = Block guard time interrupt Enabled.
2
TERRIEN
Transfer Error Interrupt Enable Bit
This field is used to enable transfer error interrupt. The transfer error states is at SC0TSR register
which includes receiver break error BEF(SC0TSR[6]), frame error FEF(SC0TSR[5]), parity error
PEF(SC0TSR[4]), receiver buffer overflow error RXOV(SC0TSR[0]) and transmit buffer overflow
error TXOV(SC0TSR[2]).
0 = Transfer error interrupt Disabled.
1 = Transfer error interrupt Enabled.
1
TBEIEN
Transmit Buffer Empty Interrupt Enable Bit
This field is used to enable transmit buffer empty interrupt.
0 = Transmit buffer empty interrupt Disabled.
1 = Transmit buffer empty interrupt Enabled.
0
RDAIEN
Receive Data Reach Interrupt Enable Bit
This field is used to enable received data interrupt.
0 = Receive data interrupt Disabled.
1 = Receive data interrupt Enabled.