Nov. 28, 2019 Page 446 of 491 Rev 1.00
MS51 32K SERIES TECHNICAL REFERENCE MANUAL
2. Set CONT (ADCCON1.4)to one for set ADC into continues conversion mode.
3. Set ADCBAH and ADCBAL registers to configure store address of conversion result.
4. Set ADCCN register to configure ADC conversion count.
5. Set HIE/FIE (ADCCON1[5]) to enable ADC conversion half done interrupt. (optional)
6. Start ADC RUN by software trigger (ADCS=1) or external trigger (ADCEX=1).