EasyManua.ls Logo

Oki MICROLINE MX Series - Page 322

Oki MICROLINE MX Series
402 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7 Diagnosing Problems
322
B51 STATUS: XX%
PROGRAMMING...
No Status message
file sucessfully
loaded and is
being saved in
flash memory.
No action is required.
B55 STATUS: SEND
PROGRAM TO EC
No EC program
downloaded and
being programed
in EC.
No action is required.
BARCODE
DAMAGED
Reverse Spools
Yes Barcode detected,
but not fully
decoded.
If barcode appears
damaged, reverse ribbon
spools. If barcode label is
present and undamaged,
clean sensor lens using
damp cloth or swab.
Check that platen gap
may be too tight
constricting ribbon
motion. Loosen gap if
needed.
BARCODE
MISSING
Install New RBN
Yes No barcode seen
on the ribbon
spool. Indicates
missing label or
damaged or dirty
sensor.
If label is missing, install
new ribbon. If barcode
label is present and
undamaged, clean sensor
lens using damp cloth or
swab.
BUFFER OVERRUN Yes Receive overrun
(serial interface).
Check printer serial port
configuration setup.
Ensure the baud rate and
data protocol match both
host and printer settings.
Table 15. LCD Message Troubleshooting Table
Displayed Message
Can User
Correct?
Explanation Solution

Table of Contents

Other manuals for Oki MICROLINE MX Series