Appendices
A-2
CJ2M CPU Unit Pulse I/O Module User’s Manual
A-1 Flag Operations during Pulse Output
The flags related to pulse outputs are refreshed at the following times.
When PULS(886) is executed
When pulse output operation is started or stopped by SPED(885), ACC(888), PLS2(887), INI(880), or
ORG(889)
When the Reset Flag is turned ON
When the operating status of the CPU Unit changes, i.e., when power is turned ON or when opera-
tion is started or stopped
Relationship between Flag Changes and Refresh Timing
---: No change, : Both ON and OFF, : ON Only, : OFF Only, 0: Cleared to 0
*1 Operation is according to the Clear Origin at Limit Input Signal setting in the PLC Setup.
*2 The PV and Overflow/Underflow Flags are cleared when a limit input turns ON and the origin is set to be unde-
fined.
*3 If the limit input function is set in the PLC Setup to always be enabled even when the limit input signal is set to
be used for a function other than the origin search function, an error will occur if the origin input (AR) turns ON.
PVs
Accel/Decel Flags
Overflow or Underflow Flags
Setting the number of pulses
Pulse output completed
Pulse output in progress
No-origin Flag
At-origin Flag
Pulse Output Stopped Error Flag
PWM output in progress
Interrupt Feeding In-progress Flag
Interrupt Feeding Error Flag
PULS (886) --- --- --- --- --- --- ---
---
*3
--- --- ---
SPED(885) Changes --- ↓↓↑--- ↑↓
---
*3
--- --- ---
ACC(888) Changes ↓↓↑--- ↑↓
---
*3
--- --- ---
PLS2(887) Changes ↑↓ ↑↓ --- ↑↓ ↑↓ --- ↑↓
---
*3
--- --- ---
IFEED(892) Changes ↓↓↑--- ↑↓
---
*3
--- ↑↓ ↑↓
PWM(891) --- --- --- --- --- --- --- ---
---
*3
--- ---
INI(880) Changes ↓↓↓--- ↓↓
---
*3
↓↓---
ORG
(889)
Origin search Changes ↑↓ --- --- ↓↑↑--- --- ---
Origin return Changes ↑↓ --- --- ↑↓ ↑↓ ---
---
*3
--- --- ---
Operation starts. 0 ↓↓↓↓↓↑---
---
*3
--- ↓↓
Operation stops. --- --- ↓↓↓--- ---
---
*3
↓↓---
Reset Changes --- --- --- --- ↑↓
---
*3
--- --- ---
Power ON 0 ↓↓↓↓↓↑↓↓↓↓↓
Stop at limit input with
origin held
*1
Changes --- --- --- --- ---
↑↓
*3
--- ---
Stop at limit input with
undefined origin
*1
0
*2
*2
--- --- ↓↑---
↑↓
*3
--- ---

Table of Contents

Other manuals for Omron CJ2H-CPU6*-EIP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CJ2H-CPU6*-EIP Series and is the answer not in the manual?

Omron CJ2H-CPU6*-EIP Series Specifications

General IconGeneral
BrandOmron
ModelCJ2H-CPU6*-EIP Series
CategoryController
LanguageEnglish

Related product manuals