EasyManuals Logo

Omron F3SJ-A series User Manual

Omron F3SJ-A series
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #59 background imageLoading...
Page #59 background image
41
F3SJ-A
User’s Manual
Chapter2 Muting System
System Configuration and Functions
E
Override Function
The override function forcibly turns the safety outputs ON when the muting start condition is not
satisfied. If a workpiece stops while passing through the detection zone of the F3SJ, as shown below,
causing a muting error, the normal state cannot be recovered unless the workpiece is removed from
the muting sensors and the detection zone of the F3SJ. However, the override function will mute the
safety outputs of the F3SJ so that the conveyor can be restarted to move the workpiece out of the
muting sensors and F3SJ detection zone.
The override function can be enabled for up to 60s.
The muting lamp (external indicator) blinks while overriding.
The muting and override functions disable the safety functions of the device. You must ensure safety
using other method when these functions are operating.
Muting lamps (external indicators) that indicate the state of the muting and override functions must be
installed where they are clearly visible to workers from all the operating positions.
Install the switch that uses hold-to-run device such as a spring-return key switch and is installed in a
location that provides a clear view of the entire hazardous zone and where it cannot be activated from
within the hazardous zone. Make sure that nobody is in the hazardous zone before activating the
override function.
Override Start Conditions
If all of the following conditions are present in the F3SJ, the override function starts. The override
function can be put into effect even when there is a muting error.
1. If either muting input 1 or 2 is ON (1 or more muting sensors are turned ON by a workpiece)
2. The F3SJ is blocked and the output is OFF
3. Under the conditions of 1 and 2 shown above, the reset input changes from ON to OFF and the test
input changes from OFF to ON at the same time. The changing time of these 2 inputs must be 0.3s
or less.
F3SJ
F3SJ
B1
A1
Workpiece
Reflector
Reflector
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com

Table of Contents

Other manuals for Omron F3SJ-A series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron F3SJ-A series and is the answer not in the manual?

Omron F3SJ-A series Specifications

General IconGeneral
BrandOmron
ModelF3SJ-A series
CategoryAccessories
LanguageEnglish

Related product manuals