3-17
3 Configuring Axes and Axes Groups
NJ/NX-series CPU Unit Motion Control Users Manual (W507)
3-2 Axis Setting Procedure
3
3-2-2 Setting Procedure
Click each of the icons in the Axis Parameter Settings Tab Page.
The settings for each icon are displayed on the Axis Parameter Settings Tab Page.
Right-click Axis Settings in the Multiview Explorer and select Axis Setting Table to enable setting the
axes parameters for all axes at the same time.
When making operation settings such as the display unit, electronic gear (unit conversion for-
mula), maximum velocity, or maximum acceleration/deceleration, be sure to use appropriate val-
ues for the operating conditions of the device.
Setting Axis Parameters

Table of Contents