13 PWM Outputs
13-2
CP2E CPU Unit Software User’s Manual(W614)
13-1 PWM Outputs (Variable-duty-factor
Pulse Outputs)
PWM outputs can be used only with the CP2E N/Sîš…îš…-type CPU Unit with transistor outputs.
A PWM (Pulse Width Modulation) pulse can be output with a specified duty factor. The duty factor is the
ratio of the pulse’s ON time and OFF time in one pulse cycle. Use the PWM instruction to generate
PWM pulses from a built-in output. The duty factor can be changed during pulse output.
z Application example
• Controlling temperature on a time-proportional basis using the PWM output.
• Controlling the brightness of lighting.
* The duty factor accuracy declines significantly at high frequencies because of limitations in the output circuit at
high frequencies.
Additional Information
For N30/40/60 CPU Units, the output indicator of terminal 01 on terminal block CIO100 is always
lit during PWM output.
Specifications
Item Specification
Duty factor 0.0% to 100.0% in 0.1% increments
(Duty factor accuracy is +1%/-0% at 10 kHz, +5%/-0% at 10 to 32 kHz .)
Frequency 2.0 Hz to 6,553.5 Hz (Set in 0.1-Hz increments.)*
2 Hz to 32,000 Hz (Set in 1-Hz increments.)*
Output mode Continuous mode
Instruction PWM
Duty factor:50%
100%
50%
75%
15%
Duty factor:15%
Duty factor:75%
Built-in output
PWM output
Period is determined
by frequency

Table of Contents

Other manuals for Omron SYSMAC CP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CP Series and is the answer not in the manual?

Omron SYSMAC CP Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CP Series
CategoryComputer Hardware
LanguageEnglish

Related product manuals