5-13
5 I/O Memory
CP2E CPU Unit Software User’s Manual(W614)
5-6 Timer Area (T)
5
5-6 Timer Area (T)
The Timer Area contains Timer Completion Flags (1 bit each) and timer PVs (16 bits each). The Com-
pletion Flag is turned ON when a decrementing timer PV reaches 0 (counting out) or an increment-
ing/decrementing timer PV reaches the set value or 0.
Timer numbers range from T0 to T255.
z Types of Timers
The following table shows which instructions are used to refresh timer PVs in BCD and binary mode.
Timer numbers 0 to 255 are used by all timers listed above.
Note Only timer numbers 0 to 15 can be used in 1ms TIMER (TMHH/TMHHX).
z Timer Example: Timer Number 0 and a Timer Set Value of 1 s
Overview
Notation
Range
Details
Timer instruction BCD mode Binary mode
HUNDRED-MS TIMER TIM TIMX
TEN-MS TIMER TIMH TIMHX
ONE-MS TIMER TMHH TMHHX
ACCUMULATIVE TIMER TTIM TTIMX
T
Time number: 002
I/O memory area designator: T
002
· BCD mode
· Binary mode
Timer Completion Flag
Timer Completion Flag
TIM
000
#10
TIMX
000
#A
T000
T000
or &10

Table of Contents

Other manuals for Omron SYSMAC CP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CP Series and is the answer not in the manual?

Omron SYSMAC CP Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CP Series
CategoryComputer Hardware
LanguageEnglish

Related product manuals