Chapter 11: Status Codes
LED
Status
Code
eV+
Error
Message
eV+
Error
Code
Explanation User Action
of the ESTOP and
re-enable high
power.
F1 *E-STOP detected
by robot*
-643 The End-Of-Arm Break-
away Sensor has tripped
(open circuit). Reporting
of this error can be
enabled / disabled via Sys-
mac Studio.
Re-close the break-
away circuit and re-
enable high power.
FM None N/A Firmware version mis-
match.
Contact your local
OMRON support.
#
h# *Robot over-
heated*
-606 The temperature sensor
on the embedded pro-
cessor board is at its tem-
perature limit.
Try slowing the
motion or insert
pauses. Also, check
for excessive ambi-
ent temperature,
inadequate vent-
ilation, and proper
function of any cool-
ing fans.
#
H# *Motor over-
heating* Mtr #
-1016 The motor encoder tem-
perature sensor indicates
an overtemperature.
Reduce robot speed,
acceleration and/or
deceleration
motions, or intro-
duce delays in the
application cycle to
give the motor an
opportunity to cool.
hV *RSC power fail-
ure*
-670 The high-voltage DC bus
for the amplifiers is out of
bounds (too high or low).
Can occur when AC
power is unex-
pectedly removed.
Check AC con-
nections and re-
enable high power.
If the error persists,
contact your local
OMRON support.
#
I# None N/A Servo initialization
stages. These steps nor-
mally sequence (I0, I1,
…) on the display during
normal system boot.
None, unless an ini-
tialization code per-
sists longer than 30
seconds. Could indic-
ate servo ini-
tialization failure.
Contact your local
OMRON support.
21861-000 Rev A Viper 650 and 850 Robot with EtherCAT 141