Page #140 background image
Preparing to Service
“Obtaining the Chassis Serial Number” on page 142
“Shutting Down a Server Node and Powering Off the System” on page 143
“Performing Electrostatic Discharge and Antistatic Prevention Measures” on page 146
“Removing Server Nodes From the System Chassis” on page 147
“Removing the Server Node Top Cover” on page 149
“Removing the Middle Section of the System Top Cover” on page 150
Component Replacement Policy (CRUs and FRUs)
Note - Information in this appendix does NOT apply to Oracle Database Appliance X3-
2, Oracle Database Appliance X4-2, Oracle Database Appliance X5-2 or Oracle Database
Appliance X6 series. Refer to the preceding chapters in this document for information on
servicing those systems.
The replaceable components in your Oracle Database Appliance Version 1 are designated
as either field-replaceable units (FRUs) or customer-replaceable units (CRUs). Some can be
replaced with the power on, some require the powering off of a server node, and some require
the powering off of the entire system chassis.
A part designated as a FRU must be replaced by Oracle-qualified service technician.
A part designated as a CRU can be replaced by a person who is not an Oracle-qualified
service technician.
The following table lists replaceable components, their service designation (CRU or FRU), and
the system power policy related to servicing the component.
Component Policy
Storage drives and boot drives
(CRU)
Hot-pluggable – Can be removed and replaced when the system is powered
on.
Fan modules (CRU) Hot-pluggable – Can be removed and replaced when the system is powered
on.
Power supplies (CRU) Hot-pluggable – Can be removed and replaced when the system is powered
on.
Air duct (FRU) Cold service, server node – Can only be removed and replaced when the
server node is powered off. The other server node and the system chassis can
remain on.
DIMMs (CRU) Cold service, server node – Can only be removed and replaced when the
server node is powered off. The other server node and the system chassis can
remain on.
140 Oracle Database Appliance Service Manual • November 2017

Table of Contents

Other manuals for Oracle Database Appliance X6-2-HA