Oracle Database Appliance Version 1 Status Indicators
Indicator/LED: Color State Meaning
■ Steady on – A fault has been detected with the fan.
Note - The front and rear panel Service Required LEDs are also lit if the system
detects a fan module fault.
Storage and Boot Drive Status Indicators
Each storage drive for Oracle Database Appliance Version 1 includes three LEDs. They are the
same on the front storage drives and the rear-mounted boot drives. See the following table.
Callout Indicator/LED: Color State Meaning
1 Ready to Remove: blue ■ Off – Normal operation.
■ Fast blink – The system is preparing a disk drive for safe removal
but it is not ready yet.
■ Steady on – The disk drive can be safely removed.
2 Service Required: amber ■ Off – Normal operation.
■ Steady on – A fault is present in the disk drive.
3 OK/Activity: green ■ On – The drive is installed and recognized by the system but
there is no drive activity.
■ Blink – The LED blinks randomly in response to data being
written to or read from the drive.
■ Off – The drive is powered off or the installed drive is not
recognized by the system.
Power Supply Status Indicators
There are three status LEDs on each power supply for Oracle Database Appliance Version 1, as
shown in the following table.
56 Oracle Database Appliance Service Manual • November 2017