Page #86 background image
Replace a Storage Shelf HDD or SSD (CRU)
Replace a Storage Shelf HDD or SSD (CRU)
Note - After a physical insertion or removal action of a storage component (such as a disk or
SAS cable), you should wait before performing the next action to allow the system software to
fully process the event. This could take several minutes to complete.
1.
Locate the failed drive on the front of the storage shelf.
Look for the drive with its Service Required indicator and/or Ready-to-Remove indicator lit.
Caution - Equipment damage. Do not remove a drive unless you have an immediate
replacement.
2.
Remove the drive:
For the DE3-24C, press the release button [1] to release the drive lever. For the DE2-24C,
slide the release latch as indicated by the debossed arrow to release the drive lever. Then,
rotate the lever open and, grasping the drive body, slide the drive out of the storage shelf [2].
86 Oracle Database Appliance Service Manual • November 2017

Table of Contents

Other manuals for Oracle Database Appliance X6-2-HA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle Database Appliance X6-2-HA and is the answer not in the manual?

Oracle Database Appliance X6-2-HA Specifications

General IconGeneral
BrandOracle
ModelDatabase Appliance X6-2-HA
CategoryStorage
LanguageEnglish

Related product manuals