Replace the Battery
Set 'datetime' to '081221302016'
set 'timezone' to 'EDT'
-> show -d properties /SP/clock
Properties
datetime = Mon Aug 22 13:20:16 2016
timezone = EDT (EST5EDT)
uptime = 2 days 19:56:49
usentpserver = disabled
b.
If the SP policy HOST_POWER_ON was enabled before you replaced the battery,
you must re-enable it.
-> set /SP/policy HOST_POWER_ON=enabled
c.
If the /SP/clock usentpserver property was enabled before you replaced the
battery, you must re-enable it.
-> set /SP/clock usentpserver=enabled
4.
Verify the battery.
-> show /SYS/MB/BAT
Related Information
“Identify Faulted Components” on page 23
120 SPARC T8-1 Server Service Manual • January 2022