Remove a Drive or Drive Filler
Caution - The latch is not an ejector. Do not bend it too far to the right. Doing so can damage
the latch.
a.
Push the release button to open the latch.
b.
Unlock the drive by moving the latch to the right.
c.
Grasp the latch and pull the drive out of the slot.
Caution - When you remove a drive, replace it with a drive filler or another drive. Otherwise,
the server might overheat due to improper airflow.
9.
Install a replacement drive or a drive filler.
See “Install a Drive or Drive Filler” on page 65.
Related Information
“Determine Which Drive Is Faulty” on page 61
“Install a Drive or Drive Filler” on page 65