  • J
    joshuajonesSep 9, 2025
    What to do if Orphee Measuring Instruments displays 'CYCLE: DOOR OPENED'?
    • M
      Melinda LangSep 9, 2025
      If the Orphee Measuring Instruments displays 'CYCLE: DOOR OPENED', close the door.
  • E
    eturnerAug 25, 2025
    What to do if Orphee MYTHIC 18 shows 'No results' and there is no HGB?
    • L
      lisaortizAug 25, 2025
      If the Orphee Measuring Instruments displays 'No results' and there is no HGB, check the bath wires, the lysis level, and ensure the right lysis tubing is correctly connected to the WBC bath.
  • H
    Heather MullinsAug 25, 2025
    What to do if Orphee MYTHIC 18 shows 'No results' because there is no HCT & PLT?
    • D
      David GarnerAug 26, 2025
      If the Orphee Measuring Instruments displays 'No results' because there is no HCT & PLT, check the bath wires. If the issue persists, perform a Cleaning Cycle, and if still unsuccessful, follow with a Bleach cycle.
  • R
    Randall TuckerSep 23, 2025
    Why is diluent leaking around the needle during the run cycle of Orphee Measuring Instruments?
    • V
      vjensenSep 23, 2025
      If the Orphee Measuring Instruments displays 'Diluent leaks around the needle during the run cycle', check the rinsing needle block for clots and clean it if necessary (see section 9.3.2).
  • M
    Miranda WolfeSep 9, 2025
    What to do if Orphee MYTHIC 18 displays 'INIT PRINTER'?
    • M
      Mrs. Jennifer MolinaSep 9, 2025
      If the Orphee Measuring Instruments displays 'INIT PRINTER', switch on the printer or invalidate the printings.
  • R
    Rachel SmithSep 14, 2025
    What to do if Orphee Measuring Instruments displays 'THE CLEANER USED IS OUT OF DATE'?
    • J
      Julia GibsonSep 14, 2025
      If the Orphee Measuring Instruments displays 'THE CLEANER USED IS OUT OF DATE', replace the bottle and perform a prime Cleaner.
  • D
    derrick71Sep 4, 2025
    What to do if Orphee MYTHIC 18 displays 'HARDWARE: SYSTEM ERROR'?
    • T
      Tammy HardinSep 4, 2025
      If the Orphee Measuring Instruments displays 'HARDWARE: SYSTEM ERROR', restart the Mythic.
  • C
    Christopher WestSep 4, 2025
    What to do if Orphee Measuring Instruments displays 'START UP CYCLE FAILED'?
    • U
      uaustinSep 4, 2025
      If the Orphee Measuring Instruments displays 'START UP CYCLE FAILED', perform a new start up cycle.
  • A
    Allison KimSep 23, 2025
    What to do if Orphee MYTHIC 18 displays 'BACKUP : FOLDER NOT FOUND'?
    • V
      vangjamesSep 23, 2025
      If the Orphee Measuring Instruments displays 'BACKUP : FOLDER NOT FOUND', restart the Mythic.
  • V
    victoriajohnsonAug 29, 2025
    What does it mean if Orphee Measuring Instruments displays 'BACKUP : MEMORY IS ALMOST FULL. PLEASE DELETE RESULTS'?
    • L
      Lisa HurleyAug 29, 2025
      If the Orphee Measuring Instruments displays 'BACKUP : MEMORY IS ALMOST FULL. PLEASE DELETE RESULTS', delete results.

Summary

IMPORTANT SAFETY INSTRUCTIONS

General Safety Warnings

Key safety warnings including reading manual, operator training, and handling metal edges.

Electromagnetic Immunity Guidance

INTRODUCTION

Installation Safety Reminder

Emphasizes reading the user's manual before installation or maintenance.

FLUIDICS SYSTEM

Fluidics Module Overview

Fluidics Parts Description

ELECTRIC & ELECTRONIC COMPONENTS

Board Overview and ESD Precautions

Lists the three main boards and provides critical ESD handling instructions.

Electronic System Diagram

Wiring Diagram - General View

DATA OUTPUT FORMAT

Routine Results Data Format

PARTS LIST AND BLOW-UP VIEWS

SOFTWARE OPERATION

Parameter Adjustment Procedures

INSTRUMENT MAINTENANCE

Maintenance Safety Precautions

Mandatory safety measures, including wearing gloves and using disinfectant.

Concentrated Cleaning Procedure

Clean Out Procedure for Transportation

REPAIRING AND REPLACEMENT

Repair Safety and Emergency Stop

Emphasizes safety measures and the emergency stop procedure.

Counting Baths Module Repair

Syringe Module Repair

Complete Syringe Module Replacement

Electronic Board Replacement Precautions

Main Board Replacement Procedure

Fuse and Battery Replacement

Preamplifier Board Replacement

TROUBLESHOOTING

Analytical Problem Diagnosis

Table addressing issues with WBC, RBC, and HGB results and their solutions.

Troubleshooting Error Messages