Chapter 1. Programming Site Data
30 DigitalFlow™ DF868 Multipurpose Ultrasonic Liquid Flowmeter Programming Manual (2-Channel)
1.7.1 Setting the Clock
Use the CLOCK submenu to enter the current date and time. While following the programming instructions, refer to
the menu map in Figure 12 on page 99.
1. To enter the GLOBAL menu, press [F3]=GLOBL.
2. To enter the CLOCK submenu, press [F1]=CLOCK.
1.7.2 Setting the Date
3. The first prompt displays the programmed Date.
If the displayed date is correct, press [F1] and proceed to step 4.
If the displayed date is incorrect, press [F2] to change the date, and complete the steps below.
a.
Enter the current Year and press [ENT]. The allowable range is 0 to 99.
b. Use the [, [ and [F1]-[F4] keys to select the current Month.
c. Enter the current Day and press [ENT]. The allowable range is 1 to the number of days in the current month.
1.7.3 Setting the Time
4. The first prompt displays the programmed Time.
If the displayed time is correct, press [F1] and return to the Global PROGRAM.
If the displayed time is incorrect, press [F2] to change the time, and complete the steps below.
a.
Press [F1] = AM or [F2] = PM. Then enter the current Hour and press [ENT]. The allowable range is 1 to 12.
Note: A time of 12 PM represents Noon and a time of 12 AM represents Midnight.
b. Enter the current Minutes and press [ENT]. The allowable range is 0 to 59.
c. Enter the current Seconds and press [ENT]. The allowable range is 0 to 59.
Procedure Options
After completing the above steps, the meter returns to the Global PROGRAM. Continue as follows:
To continue programming the meter, refer to the menu maps in Appendix A and navigate to the desired menu.
Then, proceed to the appropriate section of this manual for instructions.
To leave the User Program and retain the previous settings, press [EXIT] twice and then press [F1] = NO at the
SAVE prompt. Any programming changes will be discarded and you will be returned to the data display.
To leave the User Program and return to measurement mode, press [EXIT] twice and then press [F2] = YES at the
SAVE prompt.Your programming changes will be entered into the meter’s memory, and you will be returned to
the data display.