EasyManua.ls Logo

Panametrics DigitalFlow DF868 - START DATE Prompt; END TIME Prompt; END DATE Prompt

Panametrics DigitalFlow DF868
160 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 3. Logging Data
68 DigitalFlow™ DF868 Multipurpose Ultrasonic Liquid Flowmeter Programming Manual (2-Channel)
3.2.3 START DATE Prompt
11. Press [F1] to accept the displayed Start Date or press [F2] to enter a different start date. To start logging today,
press [F3].
If OK or TODAY was selected, proceed to step 12 for a non-circular log or to step 14 for a circular log.
Otherwise, continue with the next prompt to Edit the Start Date.
a.
Enter the desired Year and press [ENT]. The acceptable range is 0 to 99.
b. Use the [, [ and [F1]-[F4] keys to select the desired Month.
c. Enter the desired Day and press [ENT]. The acceptable range is 1 to the number of days in the selected
month (28, 29, 30 or 31).
3.2.4 END TIME Prompt
12. Press [F1] to accept the displayed End Time or press [F2] to enter a different end time. To select a specific time
period for the log to run, press [F3].
If OK was selected, proceed to the END DATE prompt.
If TIMED was selected, proceed to the LOG TIME prompt.
If EDIT was selected, complete the steps below.
Note: The log END TIME must exceed the log START TIME by at least five minutes. Failure to observe this restriction
will result in an error message.
a.
Press [F1] for AM or press [F2] for PM. Then, enter the desired Hour and press [ENT]. The acceptable range is 1 to 12.
b. Enter the desired Minutes and press [ENT]. The acceptable range is 0 to 59.
c. Enter the desired Seconds and press [ENT]. The acceptable range is 0 to 59.
3.2.5 END DATE Prompt
13. Press [F1] to accept the displayed End Date or press [F2] to enter a different end date. To end the log today, press
[F3].
If OK or TODAY was selected, proceed to the TIME INCREMENT prompt.
Otherwise, complete the steps below.
a.
Enter the desired Year and press [ENT]. The acceptable range is 0 to 99.
b. Use the [, [ and [F1]-[F4] keys to select the desired Month.
c. Enter the desired Day and press [ENT]. The acceptable range is 1 to the number of days in the selected
month (28, 29, 30 or 31). The program proceeds to step 15.

Table of Contents