29
Switching the focus operation and iris
operation
The operations of the FOCUS dial and IRIS dial can be switched
1 Press the MENU button
2 Open RP SETUP menu [25]
3 Turn the F1 dial to display the “1 FOCUS/IRIS” item
1.FOCU S/IRIS
STANDARD
4 Turn the F2 dial to select “EXCHANGE” or
“STANDARD”, and then press the F2 dial to confirm the
selection
EXCHANGE : Switches the operations of the FOCUS dial and IRIS
dial
When this is set to “EXCHANGE”, the operations
of the auto focus button and auto iris button are
also switched
The one‑touch auto focus button is disabled
Operation of the FOCUS SPEED dial is disabled
(SPEED is fixed to the value set at the time when
this setting was changed to EXCHANGE)
STANDARD : Restores the default operations of the FOCUS dial
and IRIS dial
Setting the LCD panel backlight
The backlight of the LCD panel can be turned on or off
It can also be set to turn off automatically
1 Press the MENU button
2 Open RP SETUP menu [25]
3 Turn the F1 dial to display the “3 LCD BACKLIGHT”
item
3.LCD BACKLI GHT
Off
4 Turn the F2 dial to select a setting, and then press the
F2 dial to confirm the selection
On : Turns on the backlight
Off : Turns off the backlight
60, 120, 180 : Turns off the backlight automatically when the unit
has not been operated within the set time (60, 120,
or 180 minutes)
The backlight turns off after the time elapses and
then turns on again when the unit is operated
Configuring the unit operation settings (continued)