Appendix B
Troubleshooting
NOTE: This document is CONFIDENTIAL and must be used exclusively for the operation of PAX programs. It may not be
duplicated, published, or disclosed without prior written permission from PAX.
.
229
General Troubleshooting, Continued
“App. Incompatible Data will be lost!”
A new application has been loaded. This application is not compatible with the
previous application’s data (transaction) format.
If there are transactions still in the terminal they need to be batched, the previous
application should be re-loaded so that the transactions can be batched. If this is
the case, reboot the terminal and press MENU to return to the monitor download
menu. Re-load the old application and parameters and close the batch. Load the
new application again.
If there are no open batches, press ENTER to complete the new load.
“Application: Error In Parameters!”
An error occurred while reading the protocol parameters. Re-load the terminal’s
parameters. This error can also occur if the Baud rate on the setting tab on PC
LOADER is not set to 115200.
“EDC ERROR!”
Perform a file system Rebuild from Monitor Menu with the PC LOADER.
WARNING, a file system Rebuild erases all transaction data and restarts the
application.
“PARAMETERS ERROR”
Phone card parameters are either missing or are corrupted. Re-load the terminal’s
parameters.
“Prm Err: From:”
An error occurred while reading the protocol parameters. Re-load the terminal’s
parameters.
“WRONG PRM BLOCK RELOAD PARAMS!”
Re-load the terminal’s parameters.
“FILE OPEN ERROR”
Perform a file system Rebuild from Monitor Menu with the PC LOADER.
WARNING, a file system Rebuild erases all transaction data and restarts the
application.