Diagnostic Software
EN 80 DVDR70 & DVDR75/0x15.
Nucleus Name DS_SYS_EepromDownload
Nucleus Number 1206
Description Download a file with the contents of the NVRAM for the analogue board or the digital
board from the service PC to the recorder, by using the X-modem protocol
User Input Choose one of the following parameters for the nucleus:
1. Download the contents of the NVRAM of the digital board
2. Download the contents of the NVRAM of the analogue board
Choose in the terminal of the control PC -> transfer -> send file.
Select X-modem protocol. Then choose a file with the Browse button in the dialogue
and click on send.
Example DS:> 1206 1
120600:
Test OK @
Nucleus Name DS_SYS_DvIdNumberGet
Nucleus Number 1208
Description Get the IEEE1394 ID
User Input None
Example DS:> 1208
120800: The DvIdNumber is: 0x0C22384E5A
Test OK @
Nucleus Name DS_SYS_IicWrite
Nucleus Number 1209
Description Perform an IIC write action on the digital board
User Input The user input the number of bytes to write followed by these bytes:
<BusID><Slave address to write to><number of bytes to write><d1><d2><..><dx>
Where the bus ID is either 0 (normally used) or 1
Example DS:> 1209 0 0xa0 1 0x6
120900: 1 Bytes written
Test OK @
Nucleus Name DS_SYS_IicRead
Nucleus Number 1210
Description Perform an IIC read action on the digital board
User Input The user inputs the number of bytes to read and the address to read them from:
<BusID><Slave address to read from><Number of bytes to read>
Where the bus ID is either 0 (normally used) or 1
Example DS:> 1210 0 0xa0 1
121000: Value read =0x06
Test OK @
Nucleus Name DS_SYS_UartWrite
Nucleus Number 1211
Description Perform an UART write action on the digital board on a specified UART
User Input The user inputs the UART to write to, the number of bytes and the bytes to be written
to the UART.
1=UART port 1 : not used
2=UART port 2 : Bit Engine
3=UART port 3 : Analogue board
<UartNr><Number of bytes to write><d1><d2><..><dx>
Example DS:> 1211 2 2 0xd1 0x01
121100:
Test OK @
Nucleus Name DS_SYS_UartRead
Nucleus Number 1212
Description Perform an UART read action on the digital board on a specified UART
User Input The user inputs the UART to read from.
1=UART port 1 : not used
2=UART port 2 : Bit Engine
3=UART port 3 : Analogue board
<UartNr >
Example DS:> 1212 2
121200: The value that was read is: 0x50 0xD1 0x00
Test OK @