Project configuration
Operating Manual PSEN sc ME 5.5 08-17
1005388-EN-01
| 38
[1]
Legend
[1] Area with limited detection capability
5.6 Installation of several adjacent safety laser scanners
When safety laser scanners must be installed in an area, it must be ensured that the safety
laser scanners do not influence each other.
This can be achieved in two ways:
With coding [ 23]: In the configuration of the detection capability for the individual safety
laser scanner, various codes must be defined,
Without coding: Install safety laser scanner at various heights or inclination.
} Change the height of the safety laser scanners
} Change the inclination of the safety laser scanners.
} Place an opaque object between the safety laser scanners