Project configuration
Operating Manual PSEN sc ME 5.5 08-17
1005388-EN-01
| 44
5.14 Determining the moment of switchover
WARNING!
Risk of injury due to loss of the safety function by switching the monit-
oring too late
Switching the monitoring of zone sets too late results in the loss of the
safety function. There may be people in the safety zone before switching.
Use switching of monitoring in time or overlapping zone sets to en-
sure that no person is in the safety zone when this area changes to a
danger zone.
[1]
[2]
t
1
t
2
t
3
t
4
[1]
[2]
[1]
[2]
[1]
[2]
Legend
t
1
Switchover time without advance
t
2
Advance of the switchover time by the input delay
t
3
Advance of the switchover time when using inputs of another device
t
4
Advance of the switchover time when using inputs of external OSSDs
[1] Monitoring zone set 1 is active
[2] Monitoring zone set 2 is active