Function description
Operating Manual PSEN sc ME 5.5 08-17
1005388-EN-01
| 17
For a violated safety zone, the OSSDs switch to the OFF state, for a violated warning zone
an indicator light unit can be switched on, for example.
Functions of the master unit in the series connection
} Supply voltage for the connected slave units
} Connection to PSENscan Configurator
} Control of the slave units in accordance with the functionality configured in PSENscan
Configurator
In a series connection, the safety outputs of a safety laser scanner PSEN sc ME 5.5 08-17
are connected to an evaluation device. On this safety laser scanner, max. three safety laser
scanners PSENscS3/5can be connected in series. The safety laser scanner PSEN sc
ME 5.5 08-17 is the master unit, the other safety laser scanners PSENscS3/5connected
to the master unit are slave units (see Order references [ 123]).
A safety laser scanner PSENscS3/5may only be connected to a safety laser scanner
PSEN sc ME 5.5 08-17.
PSENscan Configurator
PSEN sc 3/5 M/ME
PSEN sc 3/5 S
Safety controller
4.2 Stationary and mobile danger zone
Using the safety laser scanner, you can monitor a stationary or mobile danger zone, e.g.
the environment of a machine that is installed in a fixed position or an area in front of an
automated guided vehicle.
The monitored area can be divided into subsections, for which monitoring can be activated
and deactivated each.